DSP Farms Mismatch Alarm

This alarm is applicable only to Mediant 2600 and Mediant 4000.

AcDSPFarmsMismatchAlarm

Alarm

AcDSPFarmsMismatchAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.143

Description

The alarm is sent if the number of MPM modules (DSP farms) configured by the ini file parameter [DspFarmsInstalledNum] (default is 0) is greater than the actual MPM modules installed in the device’s chassis. The alarm and the parameter are used to check that all required MPMs are present and correctly installed in the device's chassis.

Default Severity

Major

Source Varbind Text

Board#1/ClusterManager#1/MT#2

Event Type

equipmentAlarm

Probable Cause

Underlying Resource Unavailable

Severity

Condition

Text

Corrective Action

Major

The number of MPMs configured by the DspFarmsInstalledNum parameter is greater than the number of MPMs installed on the chassis. This could result in a faulty or missing MPM module(s).

"Missing DSP farm was detected."

1. Check if the MPM module(s) is fully inserted into the chassis slot.
2. If an MPM module(s) was removed from the chassis, re-install it.
3. Make sure that the DspFarmsInstalledNum parameter is configured to the correct number of physical MPM modules.
4. If you have performed all the above and the alarm still exists, send a Return Merchandise Authorization (RMA) request to AudioCodes.

Cleared

The number of MPMs configured by the DspFarmsInstalledNum parameter is less than or equal to the number of MPMs installed in the chassis.

-

-